UCC3895PW
ActivePHASE-SHIFTED FULL-BRIDGE CONTROLLER WITH ENHANCED CONTROL LOGIC, 0°C TO 70°C
Deep-Dive with AI
Search across all available documentation for this part.

UCC3895PW
ActivePHASE-SHIFTED FULL-BRIDGE CONTROLLER WITH ENHANCED CONTROL LOGIC, 0°C TO 70°C
Technical Specifications
Parameters and characteristics for this part
| Specification | UCC3895PW |
|---|---|
| Clock Sync | True |
| Control Features | Frequency Control, Soft Start, Sync |
| Duty Cycle (Max) [Max] | 100 % |
| Frequency - Switching | 1 MHz |
| Mounting Type | Surface Mount |
| Number of Outputs | 1 |
| Operating Temperature [Max] | 70 °C |
| Operating Temperature [Min] | 0 °C |
| Output Configuration | Positive |
| Output Phases | 1 |
| Package / Case | 20-TSSOP |
| Package / Case [x] | 0.173 in |
| Package / Case [y] | 4.4 mm |
| Supplier Device Package | 20-TSSOP |
| Topology | Phase-Shifted Full-Bridge |
| Voltage - Supply (Vcc/Vdd) [Max] | 16.5 V |
| Voltage - Supply (Vcc/Vdd) [Min] | 10 V |
Pricing
Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly
| Distributor | Package | Quantity | $ | |
|---|---|---|---|---|
| Digikey | Tube | 1 | $ 6.33 | |
| 10 | $ 5.72 | |||
| Texas Instruments | TUBE | 1 | $ 5.57 | |
| 100 | $ 4.54 | |||
| 250 | $ 3.57 | |||
| 1000 | $ 3.03 | |||
Description
General part information
UCC3895 Series
The UCC3895 is a phase-shift PWM controller that implements control of a full-bridge power stage by phase shifting the switching of one half-bridge with respect to the other. The device allows constant frequency pulse-width modulation in conjunction with resonant zero-voltage switching to provide high efficiency at high frequencies. The part is used either as a voltage-mode or current-mode controller.
While the UCC3895 maintains the functionality of the UC3875/6/7/8 family and UC3879, it improves on that controller family with additional features such as enhanced control logic, adaptive delay set, and shutdown capability. Because the device is built using the BCDMOS process, it operates with dramatically less supply current than it’s bipolar counterparts. The UCC3895 operates with a maximum clock frequency of 1 MHz.
The UCC3895 is a phase-shift PWM controller that implements control of a full-bridge power stage by phase shifting the switching of one half-bridge with respect to the other. The device allows constant frequency pulse-width modulation in conjunction with resonant zero-voltage switching to provide high efficiency at high frequencies. The part is used either as a voltage-mode or current-mode controller.
Documents
Technical documentation and resources