Catalog
Switching Power Supplies 65W 48V 1360mA Open Frame
Switching Power Supplies 65W 48V 1360mA Open Frame
Switching Power Supplies 65W 48V 1360mA Open Frame
| Part | Current - Output 1 | Minimum Load Required | Applications | Voltage - Output 1 | Size / Dimension [z] | Size / Dimension [x] | Size / Dimension [z] | Size / Dimension [x] | Size / Dimension [y] | Size / Dimension [y] | Features | Operating Temperature [Max] | Operating Temperature [Min] | Efficiency | Mounting Type | Voltage - Isolation | Number of Outputs | Type | Approval Agency | Size / Dimension [y] | Size / Dimension [z] |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RECOM Power | 4.33 A | Medical | 15 V | 26.5 mm | 76.2 mm | 1.04 in | 3 " | 2 in | 50.8 mm | Adjustable Output DC Input Capable Universal Input | 85 °C | -40 °C | 93.5 % | Chassis Mount | 4000 V | 1 | Open Frame | CE cURus | |||
RECOM Power | 10 A | Medical | 5 V | 26.5 mm | 76.2 mm | 1.04 in | 3 " | 2 in | 50.8 mm | Adjustable Output DC Input Capable Universal Input | 85 °C | -40 °C | 90 % | Chassis Mount | 4000 V | 1 | Open Frame | CE cURus | |||
RECOM Power | 10 A | Medical | 5 V | 26.5 mm | 76.2 mm | 1.04 in | 3 " | 2 in | 50.8 mm | Adjustable Output DC Input Capable Universal Input | 85 °C | -40 °C | 90 % | Chassis Mount | 4000 V | 1 | Open Frame | CE cURus | |||
RECOM Power | 2.71 A | Medical | 24 V | 26.5 mm | 76.2 mm | 1.04 in | 3 " | 2 in | 50.8 mm | Adjustable Output DC Input Capable Universal Input | 85 °C | -40 °C | 93.5 % | Chassis Mount | 4000 V | 1 | Open Frame | CE cURus | |||
RECOM Power | 5.42 A | Medical | 12 V | 26.5 mm | 76.2 mm | 1.04 in | 3 " | 2 in | 50.8 mm | Adjustable Output DC Input Capable Universal Input | 85 °C | -40 °C | 92.5 % | Chassis Mount | 4000 V | 1 | Open Frame | CE cURus | |||
RECOM Power | 1.36 A | Medical | 48 V | 26.5 mm | 76.2 mm | 1.04 in | 3 " | 2 in | 50.8 mm | Adjustable Output DC Input Capable Universal Input | 85 °C | -40 °C | 93 % | Chassis Mount | 4000 V | 1 | Open Frame | CE cURus | |||
RECOM Power | 2.71 A | Medical | 24 V | 91.4 mm | 1.31 " | 3.6 in | 2.38 " | Adjustable Output DC Input Capable Universal Input | 85 °C | -40 °C | 93.5 % | Chassis Mount | 4000 V | 1 | Enclosed | CE cURus | 60.5 mm | 33.3 mm | |||
RECOM Power | 1.36 A | Medical | 48 V | 91.4 mm | 1.31 " | 3.6 in | 2.38 " | Adjustable Output DC Input Capable Universal Input | 85 °C | -40 °C | 93 % | Chassis Mount | 4000 V | 1 | Enclosed | CE cURus | 60.5 mm | 33.3 mm | |||
RECOM Power | 1.36 A | Medical | 48 V | 26.5 mm | 76.2 mm | 1.04 in | 3 " | 2 in | 50.8 mm | Adjustable Output DC Input Capable Universal Input | 85 °C | -40 °C | 93 % | Chassis Mount | 4000 V | 1 | Open Frame | CE cURus | |||
RECOM Power | 5.42 A | Medical | 12 V | 91.4 mm | 1.31 " | 3.6 in | 2.38 " | Adjustable Output DC Input Capable Universal Input | 85 °C | -40 °C | 92.5 % | Chassis Mount | 4000 V | 1 | Enclosed | CE cURus | 60.5 mm | 33.3 mm |