AC/DC OPEN FRAME POWER SUPPLY (PSU), ITE & MEDICAL, 85V AC TO 264V AC, ADJUSTABLE, FIXED
| Part | Standard Number | Type | Applications | Operating Temperature [Min] | Operating Temperature [Max] | Approval Agency | Minimum Load Required | Mounting Type | Power (Watts) | Power (Watts) | Size / Dimension [z] | Size / Dimension [x] | Size / Dimension [x] | Size / Dimension [y] | Size / Dimension [y] | Size / Dimension [z] | Voltage - Isolation | Current - Output 1 | Features | Voltage - Output 1 | Number of Outputs |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TDK-LAMBDA | 60601-1 60950-1 62368-1 | Enclosed | ITE (Commercial) Medical | -20 °C | 70 °C | CE | Chassis Mount | 250 W | 400 W | 42.5 mm | 142 mm | 5.59 in | 90 mm | 3.54 in | 1.67 in | 4000 V | 10.42 A | Adjustable Output Remote On/Off Remote Sense Standby Output Universal Input | 24 V | 1 | |
TDK-LAMBDA | 60601-1 60950-1 62368-1 | Enclosed | ITE (Commercial) Medical | -20 °C | 70 °C | CE | Chassis Mount | 250 W | 400 W | 42.5 mm | 142 mm | 5.59 in | 90 mm | 3.54 in | 1.67 in | 4000 V | 10.42 A | Adjustable Output Remote Sense Standby Output Universal Input | 24 V | 1 | |
TDK-LAMBDA | 60601-1 62368-1 | Enclosed | ITE (Commercial) Medical | -20 °C | 70 °C | CE | Chassis Mount | 250 W | 400 W | 42.5 mm | 142 mm | 5.59 in | 90 mm | 3.54 in | 1.67 in | 4000 V | 6.94 A | Adjustable Output PFC Remote Sense Universal Input | 36 V | 1 | |
TDK-LAMBDA | 60601-1 62368-1 | Enclosed | ITE (Commercial) Medical | -20 °C | 70 °C | CE | Chassis Mount | 250 W | 400 W | 67.5 mm | 142 mm | 5.59 in | 90 mm | 3.54 in | 2.66 " | 4000 V | Adjustable Output PFC Remote Sense Universal Input | 19 V | 1 | ||
TDK-LAMBDA | 60601-1 62368-1 | Open Frame | ITE (Commercial) Medical | -20 °C | 70 °C | CE | Chassis Mount | 250 W | 400 W | 40.8 mm | 141.6 mm | 5.57 in | 85.3 mm | 3.36 " | 1.61 " | 4000 V | Adjustable Output Baseplate PFC Remote Sense Universal Input | 19 V | 1 | ||
TDK-LAMBDA | 60601-1 60950-1 62368-1 | Enclosed | ITE (Commercial) Medical | -20 °C | 70 °C | CE | Chassis Mount | 250 W | 400 W | 67.5 mm | 142 mm | 5.59 in | 90 mm | 3.54 in | 2.66 " | 4000 V | 20.83 A | Adjustable Output Remote Sense Standby Output Universal Input | 12 V | 1 | |
TDK-LAMBDA | 60601-1 60950-1 62368-1 | Enclosed | ITE (Commercial) Medical | -20 °C | 70 °C | CE | Chassis Mount | 250 W | 400 W | 42.5 mm | 142 mm | 5.59 in | 90 mm | 3.54 in | 1.67 in | 4000 V | 20.83 A | Adjustable Output Remote Sense Standby Output Universal Input | 12 V | 1 | |
TDK-LAMBDA | 60601-1 62368-1 | Open Frame | ITE (Commercial) Medical | -20 °C | 70 °C | CE | Chassis Mount | 250 W | 400 W | 40.8 mm | 141.6 mm | 5.57 in | 85.3 mm | 3.36 " | 1.61 " | 4000 V | Adjustable Output Baseplate PFC Remote Sense Universal Input | 19 V | 1 | ||
TDK-LAMBDA | 60601-1 62368-1 | Open Frame | ITE (Commercial) Medical | -20 °C | 70 °C | CE | Chassis Mount | 250 W | 400 W | 41 mm | 142 mm | 5.59 in | 90 mm | 3.54 in | 1.61 " | 4000 V | 16.67 A | Adjustable Output PFC Remote Sense Universal Input | 15 V | 1 | |
TDK-LAMBDA | 60601-1 62368-1 | Open Frame | ITE (Commercial) Medical | -20 °C | 70 °C | CE | Chassis Mount | 250 W | 400 W | 40.8 mm | 141.6 mm | 5.57 in | 85.3 mm | 3.36 " | 1.61 " | 4000 V | 6.94 A | Adjustable Output Baseplate PFC Remote Sense Universal Input | 36 V | 1 |