AC/DC CONVERTER 24V 50W
| Part | Power (Watts) | Voltage - Input [Max] | Voltage - Input [Min] | Features | Type | Applications | Voltage - Isolation | Voltage - Output 1 | Efficiency | Standard Number | Approval Agency | Operating Temperature [Max] | Operating Temperature [Min] | Number of Outputs | Current - Output 1 | Size / Dimension [y] | Size / Dimension [x] | Size / Dimension [z] | Size / Dimension [z] | Size / Dimension [y] | Size / Dimension [x] | Mounting Type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CUI Inc. | 50 W | 277 VAC | 90 VAC | Adjustable Output Universal Input | Open Frame | ITE (Commercial) | 3000 V | 24 V | 89 % | 55024 60950-1 61000-3-2 61000-3-3 61000-6-1 61000-6-3 61204-3 | CB Scheme EN FCC IEC SIQ TUV UL | 60 °C | -20 °C | 1 | 2.1 A | 2 in | 101.6 mm | 1.32 in | 33.6 mm | 50.8 mm | 4 in | Chassis Mount |
CUI Inc. | 50 W | 277 VAC | 90 VAC | Adjustable Output Universal Input | Open Frame | ITE (Commercial) | 3000 V | 12 V | 87 % | 55024 60950-1 61000-3-2 61000-3-3 61000-6-1 61000-6-3 61204-3 | CB Scheme EN FCC IEC SIQ TUV UL | 60 °C | -20 °C | 1 | 4.2 A | 2 in | 101.6 mm | 1.32 in | 33.6 mm | 50.8 mm | 4 in | Chassis Mount |
CUI Inc. | 50 W | 277 VAC | 90 VAC | Adjustable Output Universal Input | Open Frame | ITE (Commercial) | 3000 V | 15 V | 88 % | 55024 60950-1 61000-3-2 61000-3-3 61000-6-1 61000-6-3 61204-3 | CB Scheme EN FCC IEC SIQ TUV UL | 60 °C | -20 °C | 1 | 3.4 A | 2 in | 101.6 mm | 1.32 in | 33.6 mm | 50.8 mm | 4 in | Chassis Mount |
CUI Inc. | 33 W | 277 VAC | 90 VAC | Adjustable Output Universal Input | Open Frame | ITE (Commercial) | 3000 V | 5 V | 55024 60950-1 61000-3-2 61000-3-3 61000-6-1 61000-6-3 61204-3 | CB Scheme EN FCC IEC SIQ TUV UL | 60 °C | -20 °C | 1 | 6.67 A | 2 in | 101.6 mm | 1.32 in | 33.6 mm | 50.8 mm | 4 in | Chassis Mount | |
CUI Inc. | 50 W | 264 VAC | 90 VAC | Universal Input | Open Frame | ITE (Commercial) | 3000 V | 24 V | 89 % | 55024 55032 Class B 61000-3-2 61000-3-3 62368-1 | CB Scheme CE EN FCC IEC SIQ TUV UL | 70 °C | -20 °C | 1 | 2.1 A | Chassis Mount | ||||||
CUI Inc. | 50 W | 264 VAC | 90 VAC | Universal Input | Open Frame | ITE (Commercial) | 3000 V | 12 V | 87 % | 55024 55032 Class B 61000-3-2 61000-3-3 62368-1 | CB Scheme CE EN FCC IEC SIQ TUV UL | 70 °C | -20 °C | 1 | 4.2 A | Chassis Mount | ||||||
CUI Inc. | 51 W | 264 VAC | 90 VAC | Universal Input | Open Frame | ITE (Commercial) | 3000 V | 15 V | 88 % | 55024 55032 Class B 61000-3-2 61000-3-3 62368-1 | CB Scheme CE EN FCC IEC SIQ TUV UL | 70 °C | -20 °C | 1 | 3.4 A | Chassis Mount |