AC/DC CONVERTER 60V 5000W
| Part | Applications | Voltage - Isolation | Minimum Load Required | Current - Output 1 | Mounting Type | Standard Number | Approval Agency | Type | Efficiency | Number of Outputs | Size / Dimension [z] | Size / Dimension [y] | Size / Dimension [x] | Size / Dimension [z] | Size / Dimension [x] | Size / Dimension [y] | Voltage - Output 1 | Operating Temperature [Min] | Operating Temperature [Max] | Power (Watts) | Features | Size / Dimension [y] | Size / Dimension [z] |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
XP POWER | ITE (Commercial) Medical | 4000 V | 83.3 A | Chassis Mount | 60601-1 60950-1 62368-1 | CB CE TUV UL | Enclosed | 93 % | 1 | 63.5 mm | 254 mm | 336.6 mm | 2.5 in | 13.25 in | 10 in | 60 V | -20 °C | 70 °C | 5000 W | Adjustable Output PMBus™ Remote On/Off Remote Sense Standby Output | |||
XP POWER | ITE (Commercial) Medical | 4000 V | 50 A | Chassis Mount | 60601-1 60950-1 62368-1 | CB CE TUV UL | Enclosed | 93 % | 1 | 330.2 mm | 5 in | 13 in | 5 " | 100 V | -20 °C | 70 °C | 5000 W | Adjustable Output I2C Interface Load Sharing PMBus™ Remote On/Off Remote Sense Standby Output | 127 mm | 127 mm | |||
XP POWER | ITE (Commercial) Medical | 4000 V | 104 A | Chassis Mount | 60601-1 60950-1 62368-1 | CB CE TUV UL | Enclosed | 93 % | 1 | 330.2 mm | 5 in | 13 in | 5 " | 48 V | -20 °C | 70 °C | 5000 W | Adjustable Output PMBus™ Remote On/Off Remote Sense Standby Output | 127 mm | 127 mm | |||
XP POWER | ITE (Commercial) Medical | 4000 V | 83.3 A | Chassis Mount | 60601-1 60950-1 62368-1 | CB CE TUV UL | Enclosed | 93 % | 1 | 330.2 mm | 5 in | 13 in | 5 " | 60 V | -20 °C | 70 °C | 5000 W | Adjustable Output I2C Interface Load Sharing PMBus™ Remote On/Off Remote Sense Standby Output | 127 mm | 127 mm | |||
XP POWER | ITE (Commercial) Medical | 4000 V | 25 A | Chassis Mount | 60601-1 60950-1 62368-1 | CB CE TUV UL | Enclosed | 93 % | 1 | 330.2 mm | 5 in | 13 in | 5 " | 200 V | -20 °C | 70 °C | 5000 W | Adjustable Output I2C Interface Load Sharing PMBus™ Remote On/Off Remote Sense Standby Output | 127 mm | 127 mm | |||
XP POWER | ITE (Commercial) Medical | 4000 V | 50 A | Chassis Mount | 60601-1 60950-1 62368-1 | CB CE TUV UL | Enclosed | 93 % | 1 | 63.5 mm | 254 mm | 336.6 mm | 2.5 in | 13.25 in | 10 in | 100 V | -20 °C | 70 °C | 5000 W | Adjustable Output PMBus™ Remote On/Off Remote Sense Standby Output | |||
XP POWER | ITE (Commercial) Medical | 4000 V | 25 A | Chassis Mount | 60601-1 60950-1 62368-1 | CB CE TUV UL | Enclosed | 93 % | 1 | 63.5 mm | 254 mm | 336.6 mm | 2.5 in | 13.25 in | 10 in | 200 V | -20 °C | 70 °C | 5000 W | Adjustable Output PMBus™ Remote On/Off Remote Sense Standby Output |