AC/DC DIN RAIL SUPPLY 9V 5W
| Part | Standard Number | Input Type | Features | Power (Watts) | Minimum Load Required | Size / Dimension [x] | Size / Dimension [x] | Size / Dimension [y] | Size / Dimension [z] | Size / Dimension [y] | Size / Dimension [z] | Applications | Voltage - Output 1 | Number of Outputs | Operating Temperature [Min] | Operating Temperature [Max] | AC Voltage - Input [Min] | AC Voltage - Input [Max] | Efficiency | DC Voltage - Input (Max) [Max] | DC Voltage - Input (Min) [Min] | Approval Agency | Voltage - Isolation | Current - Output (Max) [Max] | Load Regulation | Voltage - Input [Min] | Voltage - Input [Max] | Weight | Weight | Package / Case | Type | Line Regulation | Mounting Type | Current - Output 1 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
aimtec | 60601-1 | AC or DC | Universal Input | 5 W | 1.02 in | 25.9 mm | 23.1 mm | 2.99 in | 0.91 in | 75.9 mm | Medical | 9 V | 1 | -25 °C | 70 °C | 85 VAC | 264 VAC | 78 % | 370 V | 100 V | cULus cURus | 4000 V | 550 mA | |||||||||||
aimtec | Universal Input | 5 W | 2.03 in | 51.5 mm | 28 mm | 0.7 " | 1.1 in | 17.8 mm | ITE (Commercial) Medical | 5 V | 1 | -40 °C | 80 ¯C | 74 % | CB CE cURus | 1 A | 1 % | 90 VAC | 264 VAC | 30 g | 0.066 lb | 5-DIP Module | Enclosed | 1 % | Through Hole | |||||||||
aimtec | Universal Input | 5 W | 2.03 in | 51.5 mm | 28 mm | 0.7 " | 1.1 in | 17.8 mm | ITE (Commercial) Medical | 24 V | 1 | -40 °C | 80 ¯C | 76 % | CB CE cURus | 210 mA | 1 % | 90 VAC | 264 VAC | 5-DIP Module | Enclosed | 1 % | Through Hole | |||||||||||
aimtec | Universal Input | 5 W | 1.46 in | 37 mm | 24.5 mm | 0.71 in | 0.96 in | 18 mm | ITE (Commercial) | 9 V | 1 | 77 % | 560 mA | 1 % | 85 VAC 100 V | 264 VAC 370 VDC | 25 g | 0.055 lb | 26-DIP Module 5 Leads | Enclosed | 0.5 % | Through Hole | ||||||||||||
aimtec | Universal Input | 5 W | 1.46 in | 37 mm | 24.9 mm | 0.71 in | 0.97 " | 18 mm | ITE (Commercial) | 24 V | 1 | -40 °C | 70 °C | 81 % | 4000 V | 85 VAC 100 V | 264 VAC 370 VDC | Enclosed | Chassis Mount | 210 mA | ||||||||||||||
aimtec | Universal Input | 5 W | 2.03 in | 51.5 mm | 28 mm | 0.7 " | 1.1 in | 17.8 mm | ITE (Commercial) Medical | 5 V | 1 | -40 °C | 80 ¯C | 74 % | CB CE cURus | 1 A | 1 % | 90 VAC | 264 VAC | 5-DIP Module | Enclosed | 1 % | Through Hole | |||||||||||
aimtec | 5 W | 2 in | 50.8 mm | 25.4 mm | 0.6 " | 25.4 mm | 15.2 mm | ITE (Commercial) | 5 V | 1 | -25 °C | 70 °C | 78 % | CE cULus cURus | 1 A | 0.5 % | 4-DIP Module | Enclosed | 0.5 % | Through Hole | ||||||||||||||
aimtec | 60601-1 | Universal Input | 2.99 in | 76 mm | 31.5 mm | 0.94 in | 1.24 in | 24 mm | Medical | 24 V | 1 | -25 °C | 70 °C | 83 % | cULus cURus | 4000 V | Enclosed | Chassis Mount | 230 mA | |||||||||||||||
aimtec | Universal Input | 5 W | 2.03 in | 51.5 mm | 28 mm | 0.7 " | 1.1 in | 17.8 mm | ITE (Commercial) Medical | 24 V | 1 | -40 °C | 80 ¯C | 76 % | CB CE cURus | 210 mA | 1 % | 90 VAC | 264 VAC | 30 g | 0.066 lb | 5-DIP Module | Enclosed | 1 % | Through Hole | |||||||||
aimtec | 5 W | 2.03 in | 51.5 mm | 28.3 mm | 0.7 " | 1.11 in | 17.8 mm | ITE (Commercial) | 12 V | 1 | -40 °C | 95 °C | 76 % | CB CE cURus | 420 mA | 1 % | 90 VAC 130 VDC | 305 VAC 430 VDC | 30 g | 0.066 lb | 4-DIP Module | Enclosed | 1 % | Through Hole |