DC DC CONVERTER +/-15V 20W
| Part | Applications | Voltage - Input (Max) [Max] | Power (Watts) | Voltage - Output 1 [Max] | Voltage - Output 1 [Min] | Mounting Type | Efficiency | Operating Temperature [Max] | Operating Temperature [Min] | Type | Size / Dimension [x] | Size / Dimension [x] | Size / Dimension [z] | Size / Dimension [y] | Size / Dimension [y] | Size / Dimension [z] | Package / Case | Number of Outputs | Voltage - Output 2 | Approval Agency | Voltage - Isolation | Features | Current - Output (Max) | Current - Output (Max) | Voltage - Input (Min) [Min] | Current - Output (Max) [Max] | Voltage - Output 1 | Standard Number | Current - Output (Max) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
aimtec | ITE (Commercial) | 36 V | 20 W | 15 V | -15 V | Through Hole | 88 % | 85 °C | -40 °C | Isolated Module | 2 in | 50.8 mm | 0.46 in | 25.4 mm | 25.4 mm | 11.8 mm | 6-DIP Module | 2 | -15 V | CE cULus cURus | 1.5 kV | Adjustable Output Remote On/Off | 667 mA | 667 mA | 9 V | ||||
aimtec | Medical | 36 V | 20 W | Through Hole | 89 % | 85 °C | -40 °C | Isolated Module | 2.03 in | 51.5 mm | 0.47 " | 26.5 mm | 1.04 in | 12 mm | 1 | 5000 V | Remote On/Off | 9 V | 833 mA | 24 V | |||||||||
aimtec | Medical | 75 V | 20 W | Through Hole | 88 % | 85 °C | -40 °C | Isolated Module | 2.03 in | 51.5 mm | 0.47 " | 26.5 mm | 1.04 in | 12 mm | 1 | 5000 V | Remote On/Off | 18 V | 1.333 A | 15 V | |||||||||
aimtec | ITE (Commercial) | 36 V | 20 W | Chassis Mount | 89 % | 65 °C | -40 °C | Enclosed | 2.99 in | 76 mm | 1 " | 31.5 mm | 1.29 " | 25.1 mm | 1 | CE cURus | 1.5 kV | 9 V | 1.667 A | 12 V | 60950-1 | ||||||||
aimtec | ITE (Commercial) | 75 V | 20 W | 12 V | 5 V | Through Hole | 84 % | 105 ░C | -40 °C | Isolated Module | 2 in | 50.8 mm | 0.46 in | 25.4 mm | 25.4 mm | 11.8 mm | 2 | 12 V | 3000 V | Remote On/Off | 833 mA | 2 A | 18 V | ||||||
aimtec | Medical | 36 V | 20 W | Through Hole | 86 % | 85 °C | -40 °C | Isolated Module | 2.03 in | 51.5 mm | 0.47 " | 26.5 mm | 1.04 in | 12 mm | 1 | 5000 V | Remote On/Off | 9 V | 1.666 A | 12 V | |||||||||
aimtec | ITE (Commercial) | 36 V | 20 W | Through Hole | 89 % | 85 °C | -40 °C | Isolated Module | 2 in | 50.8 mm | 0.47 " | 25.4 mm | 25.4 mm | 11.8 mm | 1 | CE | 1.5 kV | Remote On/Off | 18 V | 2.22 A | 9 V | ||||||||
aimtec | ITE (Commercial) | 36 V | 20 W | Through Hole | 88 % | 85 °C | -40 °C | Isolated Module | 2 in | 50.8 mm | 0.47 " | 25.4 mm | 25.4 mm | 11.8 mm | 2 | -9 V | CE | 1.5 kV | Remote On/Off | 1.11 A | 18 V | 1.11 A | |||||||
aimtec | ITE (Commercial) | 36 V | 20 W | 12 V | -12 V | Through Hole | 88 % | 85 °C | -40 °C | Isolated Module | 2 in | 50.8 mm | 0.47 " | 25.4 mm | 25.4 mm | 11.8 mm | 2 | -12 V | CE cULus cURus | 1.5 kV | Adjustable Output Heat Sink Remote On/Off | 834 mA | 9 V | ||||||
aimtec | Medical | 36 V | 20 W | Through Hole | 86 % | 85 °C | -40 °C | Isolated Module | 2.03 in | 51.5 mm | 0.47 " | 26.5 mm | 1.04 in | 12 mm | 1 | 5000 V | Remote On/Off | 9 V | 4 A | 5 V |