AC/DC OPEN FRAME POWER SUPPLY (PSU), ITE & MEDICAL, 1 OUTPUT, 499.2W, 350.4 W, 85V AC TO 265V AC
| Part | Voltage - Output 1 | Type | Minimum Load Required | Efficiency | Operating Temperature [Min] | Operating Temperature [Max] | Approval Agency | Standard Number | Applications | Size / Dimension [y] | Size / Dimension [z] | Size / Dimension [x] | Size / Dimension [y] | Size / Dimension [x] | Size / Dimension [z] | Mounting Type | Current - Output 1 | Power (Watts) | Power (Watts) | Number of Outputs | Voltage - Input [Max] | Voltage - Input [Min] | Features | Voltage - Isolation |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TDK-LAMBDA | 24 V | Conformal Coated Open Frame | 94 % | -20 °C | 70 °C | CE | 60601-1 62368-1 | ITE (Commercial) Medical | 3.92 in | 49.5 mm | 212.1 mm | 99.6 mm | 8.35 in | 1.95 in | Chassis Mount | 14.6 A | 350 W | 499 W | 1 | 265 VAC 370 VDC | 85 VAC 120 VDC | Adjustable Output Remote On/Off Remote Sense Standby Output | ||
TDK-LAMBDA | 30 V | Enclosed | 94 % | -20 °C | 70 °C | CE | 60601-1 62368-1 | ITE (Commercial) Medical | 3.46 " | 44 mm | 183 mm | 88 mm | 7.2 in | 1.73 " | Chassis Mount | 11.65 A | 350 W | 498 W | 1 | 265 VAC 370 VDC | 85 VAC 120 VDC | Adjustable Output Remote On/Off Remote Sense Standby Output | 4000 V | |
TDK-LAMBDA | 30 V | Conformal Coated Open Frame | 94 % | -20 °C | 70 °C | CE | 60601-1 62368-1 | ITE (Commercial) Medical | 3.92 in | 49.5 mm | 212.1 mm | 99.6 mm | 8.35 in | 1.95 in | Chassis Mount | 11.65 A | 350 W | 498 W | 1 | 265 VAC 370 VDC | 85 VAC 120 VDC | Adjustable Output Remote On/Off Remote Sense Standby Output | 4000 V | |
TDK-LAMBDA | 24 V | Open Frame | 94 % | -20 °C | 70 °C | CE | 60601-1 62368-1 | ITE (Commercial) Medical | 3.46 " | 44 mm | 183 mm | 88 mm | 7.2 in | 1.73 " | Chassis Mount | 14.6 A | 350 W | 499 W | 1 | 265 VAC 370 VDC | 85 VAC 120 VDC | Adjustable Output Remote On/Off Remote Sense Standby Output | 4000 V | |
TDK-LAMBDA | 48 V | Enclosed | 94 % | -20 °C | 70 °C | CE | 60601-1 62368-1 | ITE (Commercial) Medical | 3.46 " | 44 mm | 183 mm | 88 mm | 7.2 in | 1.73 " | Chassis Mount | 7.3 A | 350 W | 499 W | 1 | 265 VAC 370 VDC | 85 VAC 120 VDC | Adjustable Output Remote On/Off Remote Sense Standby Output | 4000 V | |
TDK-LAMBDA | 30 V | Open Frame | 94 % | -20 °C | 70 °C | CE | 60601-1 62368-1 | ITE (Commercial) Medical | 3.46 " | 44 mm | 183 mm | 88 mm | 7.2 in | 1.73 " | Chassis Mount | 11.65 A | 350 W | 498 W | 1 | 265 VAC 370 VDC | 85 VAC 120 VDC | Adjustable Output Baseplate Remote On/Off Remote Sense Standby Output | 4000 V | |
TDK-LAMBDA | 48 V | Open Frame | 94 % | -20 °C | 70 °C | CE | 60601-1 62368-1 | ITE (Commercial) Medical | 3.46 " | 44 mm | 183 mm | 88 mm | 7.2 in | 1.73 " | Chassis Mount | 7.3 A | 350 W | 499 W | 1 | 265 VAC 370 VDC | 85 VAC 120 VDC | Adjustable Output Remote On/Off Remote Sense Standby Output | 4000 V | |
TDK-LAMBDA | 48 V | Conformal Coated Open Frame | 94 % | -20 °C | 70 °C | CE | 60601-1 62368-1 | ITE (Commercial) Medical | 3.92 in | 49.5 mm | 212.1 mm | 99.6 mm | 8.35 in | 1.95 in | Chassis Mount | 7.3 A | 350 W | 499 W | 1 | 265 VAC 370 VDC | 85 VAC 120 VDC | Adjustable Output Remote On/Off Remote Sense Standby Output | 4000 V | |
TDK-LAMBDA | 36 V | Enclosed | 94 % | -20 °C | 70 °C | CE | 60601-1 62368-1 | ITE (Commercial) Medical | 3.46 " | 44 mm | 183 mm | 88 mm | 7.2 in | 1.73 " | Chassis Mount | 9.7 A | 349 W 497 W | 1 | 265 VAC 370 VDC | 85 VAC 120 VDC | Adjustable Output Remote On/Off Remote Sense Standby Output | 4000 V |