15KPA280CAE3/TR13
ActiveTVS 15000W, STAND-OFF VOLTAGE = 280V, +/- 5%, BI-DIR P600 ROHS COMPLIANT: YES
Deep-Dive with AI
Search across all available documentation for this part.
15KPA280CAE3/TR13
ActiveTVS 15000W, STAND-OFF VOLTAGE = 280V, +/- 5%, BI-DIR P600 ROHS COMPLIANT: YES
Deep-Dive with AI
Technical Specifications
Parameters and characteristics for this part
| Specification | 15KPA280CAE3/TR13 |
|---|---|
| Applications | General Purpose |
| Bidirectional Channels [custom] | 1 |
| Current - Peak Pulse (10/1000µs) | 33.2 A |
| Mounting Type | Through Hole |
| Operating Temperature [Max] | 175 ░C |
| Operating Temperature [Min] | -55 °C |
| Package / Case | P600, Axial |
| Power Line Protection | False |
| Supplier Device Package | P600 |
| Type | Zener |
| Voltage - Breakdown (Min) [Min] | 312.8 V |
| Voltage - Clamping (Max) @ Ipp [Max] | 454.5 V |
| Voltage - Reverse Standoff (Typ) | 280 V |
Pricing
Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly
Description
General part information
15KPA280C-e3 Series
The 15KPA17e3 - 15KPA280CAe3 series of devices clamps dangerous high-voltage short-term transients such as those produced by the secondary effects of lightning strikes, providing circuit protection to several class levels in the IEC61000-4-5 specification. Clamping time is virtually instantaneous. It also provides protection from transients caused by inductive load dumps, induced RFI, and ESD, providing protection to IEC61000-4-2 and -4-4.