Zenode.ai Logo
Beta
K
UCC25800AQDGNRQ1 - 8-pin (DGN) package image

UCC25800AQDGNRQ1

Active
Texas Instruments

ULTRA-LOW EMI TRANSFORMER DRIVER FOR ISOLATED BIAS SUPPLIES

UCC25800AQDGNRQ1 - 8-pin (DGN) package image

UCC25800AQDGNRQ1

Active
Texas Instruments

ULTRA-LOW EMI TRANSFORMER DRIVER FOR ISOLATED BIAS SUPPLIES

Technical Specifications

Parameters and characteristics for this part

SpecificationUCC25800AQDGNRQ1
ApplicationsTransformer Driver
Current - Supply14 mA
GradeAutomotive
Mounting TypeSurface Mount
Operating Temperature [Max]125 °C
Operating Temperature [Min]-40 °C
Package / Case8-PowerTSSOP, 8-MSOP
Package / Case [custom]3 mm
Package / Case [custom]0.118 in
QualificationAEC-Q100
Supplier Device Package8-HVSSOP
Voltage - Supply [Max]34 VDC
Voltage - Supply [Min]9 V

Pricing

Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly

DistributorPackageQuantity$
DigikeyCut Tape (CT) 1$ 3.88
10$ 2.55
25$ 2.21
100$ 1.82
250$ 1.63
500$ 1.51
1000$ 1.42
Digi-Reel® 1$ 3.88
10$ 2.55
25$ 2.21
100$ 1.82
250$ 1.63
500$ 1.51
1000$ 1.42
Tape & Reel (TR) 2500$ 1.31
5000$ 1.25
7500$ 1.23
Texas InstrumentsLARGE T&R 1$ 2.19
100$ 1.81
250$ 1.30
1000$ 0.98

Description

General part information

UCC25800-Q1 Series

The UCC25800-Q1 ultra-low EMI transformer driver integrates the switching power stage, the control, and the protection circuits to simplify isolated bias supply designs. It allows the design to utilize a transformer with higher leakage inductance, but much smaller parasitic primary-to-secondary capacitance. This low-capacitance transformer design enables an order of magnitude reduction in the common-mode current injection through the bias transformer. This makes the transformer driver an ideal solution for the isolated bias supply in various automotive applications to minimize the EMI noise caused by the high-speed switching devices. The soft-switching feature further reduces the EMI noise.

The transformer driver has a programmable frequency range of 100 kHz to 1.2 MHz. This high switching frequency reduces the transformer size and footprint, as well as the overall cost of the bias supply. The integrated SYNC function allows the system bias supplies to synchronize with an external clock signal, further reducing the system level noise.

The dead-time adjusts automatically to minimize the conduction loss and simplify the design. The programmable maximum dead-time ensures power stage design flexibility.