2000316
ObsoleteTE Connectivity Measurement Specialties
TRANSDUCER 25# PRES 4-20MA
Deep-Dive with AI
Search across all available documentation for this part.

2000316
ObsoleteTE Connectivity Measurement Specialties
TRANSDUCER 25# PRES 4-20MA
Deep-Dive with AI
Technical Specifications
Parameters and characteristics for this part
| Specification | 2000316 |
|---|---|
| Accuracy | 1 % |
| Applications | Industrial Automation |
| Features | Temperature Compensated, Amplified Output |
| Maximum Pressure | 344.74 kPa |
| Maximum Pressure | 50 PSI |
| Operating Pressure | 172.37 kPa |
| Operating Pressure | 25 PSI |
| Operating Temperature [Max] | 85 °C |
| Operating Temperature [Min] | -20 C |
| Output [Max] | 20 mA |
| Output [Min] | 4 mA |
| Output Type | Analog Current |
| Package / Case | Cylinder |
| Port Size [custom] | NPT |
| Port Size [custom] | Male |
| Port Size [x] | 0.25 " |
| Port Size [x] | 6.35 mm |
| Port Style | Threaded |
| Pressure Type | Vented Gauge |
| Termination Style | Cable/Wire Leads |
| Voltage - Supply [Max] | 30 VDC |
| Voltage - Supply [Min] | 10 VDC |
2000 Series
| Part | Package / Case | Voltage - Supply [Max] | Voltage - Supply [Min] | Output Type | Accuracy | Features | Operating Pressure | Operating Pressure | Termination Style | Output [Max] | Output [Min] | Port Size | Port Size | Pressure Type | Port Style | Maximum Pressure [Max] | Maximum Pressure [Max] | Operating Temperature [Max] | Operating Temperature [Min] | Applications | Port Size [custom] | Port Size [x] | Port Size [x] | Port Size [custom] | Maximum Pressure | Maximum Pressure | Operating Pressure | Operating Pressure [x] | Operating Pressure [x] | Temperature Range [Min] | Temperature Range [Max] | Terminal Type | Diameter - Protective Tube [diameter] | Conductor Type | Length - Lead Wire | Length - Lead Wire | Element Type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TE Connectivity Measurement Specialties | Cylinder | 30 VDC | 10 VDC | Analog Current | 0.25 % | Amplified Output Temperature Compensated | 689.48 kPa | 100 PSI | Connector | 20 mA | 4 mA | Male UNF | 0.4375 " 11.11 mm | Vented Gauge | Threaded | 200 PSI | 1378.95 kPa | 100 °C | -40 °C | Industrial Automation | |||||||||||||||||
TE Connectivity Measurement Specialties | Cylinder | 30 VDC | 10 VDC | Analog Current | 1.5 % | Amplified Output Temperature Compensated | 689.48 kPa | 100 PSI | Cable | 20 mA | 4 mA | Vented Gauge | Threaded | 200 PSI | 1378.95 kPa | 85 °C | -40 °C | Industrial Automation | NPT | 0.25 " | 6.35 mm | Male | |||||||||||||||
TE Connectivity Measurement Specialties | Cylinder | 30 VDC | 10 VDC | Analog Current | 0.25 % | Amplified Output Temperature Compensated | 25 PSI | Connector | 20 mA | 4 mA | Male UNF | 0.4375 " 11.11 mm | Vented Gauge | Threaded | 100 °C | -40 °C | Industrial Automation | 344.74 kPa | 50 PSI | 172.37 kPa | |||||||||||||||||
TE Connectivity Measurement Specialties | Cylinder | 30 VDC | 10 VDC | Analog Current | 1 % | Amplified Output Temperature Compensated | 25 PSI | Cable/Wire Leads | 20 mA | 4 mA | Vented Gauge | Threaded | 85 °C | -20 C | Industrial Automation | NPT | 0.25 " | 6.35 mm | Male | 344.74 kPa | 50 PSI | 172.37 kPa | |||||||||||||||
TE Connectivity Measurement Specialties | Cylinder | 30 VDC | 10 VDC | Analog Current | 0.25 % | Amplified Output Temperature Compensated | 3447.38 kPa | 500 PSI | Connector | 20 mA | 4 mA | Vented Gauge | Threaded | 1000 PSI | 6894.76 kPa | 100 °C | -40 °C | Industrial Automation | NPT | 0.25 " | 6.35 mm | Male | |||||||||||||||
TE Connectivity Measurement Specialties | Cylinder | 30 VDC | 10 VDC | Analog Voltage | 1 % | Amplified Output Temperature Compensated | 344.74 kPa | 50 PSI | Cable/Wire Leads | 5 V | 1 V | Vented Gauge | Threaded | 100 PSI | 689.48 kPa | 85 °C | -20 C | Industrial Automation | NPT | 0.25 " | 6.35 mm | Male | |||||||||||||||
TE Connectivity Measurement Specialties | Cylinder | 30 VDC | 10 VDC | Analog Current | 1 % | Amplified Output Temperature Compensated | 25 PSI | Cable/Wire Leads | 20 mA | 4 mA | Vented Gauge | Threaded | 85 °C | -20 C | Industrial Automation | NPT | 0.25 " | 6.35 mm | Male | 344.74 kPa | 50 PSI | 172.37 kPa | |||||||||||||||
TE Connectivity Measurement Specialties | Cylinder | 30 VDC | 10 VDC | Analog Current | 0.25 % | Amplified Output Temperature Compensated | Cable 2' | 20 mA | 4 mA | Vented Gauge | Threaded | 100 °C | -40 °C | Industrial Automation | NPT | 0.25 " | 6.35 mm | Male | 137895.15 kPa | 20000 PSI | 10000 PSI | 68947.57 kPa | |||||||||||||||
TE Connectivity Measurement Specialties | 0 °C | 750 °C | Exposed Lead Wires | 3.18 mm | Non-Grounded | 35.98 in | 914 mm | J - Type | |||||||||||||||||||||||||||||
TE Connectivity Measurement Specialties | Cylinder | 30 VDC | 10 VDC | Analog Current | 1.5 % | Amplified Output Temperature Compensated | 17236.89 kPa | 2500 PSI | Cable | 20 mA | 4 mA | Vented Gauge | Threaded | 5000 PSI | 34473.79 kPa | 85 °C | -40 °C | Industrial Automation | NPT | 0.25 " | 6.35 mm | Male |
Pricing
Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly
| Distributor | Package | Quantity | $ | |
|---|---|---|---|---|
Description
General part information
2000 Series
TRANSDUCER 25# PRES 4-20MA