Zenode.ai Logo
Beta
K
LTC4214-1CMS#PBF - 10 MSOP

LTC4214-1CMS#PBF

Active
Analog Devices

HOT SWAP CONTROLLER 1-CH 16V N-CHANNEL NEGATIVE LOW VOLTAGE 10-PIN MSOP TUBE

Deep-Dive with AI

Search across all available documentation for this part.

LTC4214-1CMS#PBF - 10 MSOP

LTC4214-1CMS#PBF

Active
Analog Devices

HOT SWAP CONTROLLER 1-CH 16V N-CHANNEL NEGATIVE LOW VOLTAGE 10-PIN MSOP TUBE

Deep-Dive with AI

Technical Specifications

Parameters and characteristics for this part

SpecificationLTC4214-1CMS#PBF
ApplicationsGeneral Purpose
Current - Supply800 çA
FeaturesLatched Fault
Internal Switch(s)False
Mounting TypeSurface Mount
Number of Channels1
Operating Temperature [Max]70 °C
Operating Temperature [Min]0 °C
Package / Case10-MSOP, 10-TFSOP
Package / Case [x]3 mm
Package / Case [x]0.118 in
Programmable FeaturesUVLO, OVP, Fault Timeout, Current Limit
Supplier Device Package10-MSOP
TypeHot Swap Controller
Voltage - Supply [Max]16 V
Voltage - Supply [Min]6 V

Pricing

Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly

DistributorPackageQuantity$
DigikeyTube 1$ 9.28

Description

General part information

LTC4214 Series

The LTC4214 negative voltage Hot Swap™controller allows a board to be safely inserted and removed from a live backplane. Output current is controlled by three stages of current limiting: a timed circuit breaker, active current limiting and a fast feedforward path that limits peak current under worst-case catastrophic fault conditions.Adjustable undervoltage and overvoltage detectors disconnect the load whenever the input supply exceeds the desired operating range. The LTC4214 controls negative supplies ranging from near zero to –16V. A multifunction timer delays initial start-up and controls the circuit breaker’s response time. This response time is accelerated by sensing excessive MOSFET drain voltage, keeping the MOSFET within its safe operating area (SOA). An adjustable soft-start circuit controls MOSFET inrush current at start-up. A power good status output can enable a power module at start-up or disable it if the circuit breaker trips.The LTC4214-1 latches off after a circuit breaker fault times out. The LTC4214-2 provides automatic retry after a fault. The LTC4214 is available in the 10-pin MSOP package.ApplicationsHot Board InsertionElectronic Circuit BreakerNegative Power Supply ControlCentral Office SwitchingHigh Availability ServersDisk ArraysOptical Networking/SwitchingECL

Documents

Technical documentation and resources