1011435CH
ActiveIntegrated Power Designs
DC-DC POWER MODULES ROHS
Deep-Dive with AI
Search across all available documentation for this part.

1011435CH
ActiveIntegrated Power Designs
DC-DC POWER MODULES ROHS
Deep-Dive with AI
Technical Specifications
Parameters and characteristics for this part
| Specification | 1011435CH |
|---|---|
| Applications | ITE (Commercial), Medical |
| Approval Agency | TUV, cURus, CE, UKCA |
| Current - Output 1 | 30 A |
| Current - Output 2 | 8 A |
| Current - Output 3 | 2 A |
| Current - Output 4 | 2 A |
| Efficiency | 89 % |
| Features | Remote Sense, Universal Input, Adjustable Output |
| Minimum Load Required | False |
| Mounting Type | Chassis Mount |
| Number of Outputs | 4 |
| Operating Temperature [Max] | 70 °C |
| Operating Temperature [Min] | -20 °C |
| Power (Watts) | 200 W |
| Size / Dimension [x] | 127 mm |
| Size / Dimension [x] | 5 in |
| Size / Dimension [y] | 79.9 mm |
| Size / Dimension [y] | 3.14 in |
| Size / Dimension [z] | 1.65 " |
| Size / Dimension [z] | 41.9 mm |
| Standard Number | 60601-1, 62368-1 |
| Type | Chassis |
| Voltage - Output 1 | 5 V |
| Voltage - Output 2 | 3.3 V |
| Voltage - Output 3 | 12 V |
GRN-200 Series
| Part | Current - Output 3 | Minimum Load Required | Approval Agency | Standard Number | Type | Applications | Operating Temperature [Min] | Operating Temperature [Max] | Voltage - Output 1 | Current - Output 4 | Power (Watts) | Features | Current - Output 2 | Number of Outputs | Efficiency | Size / Dimension [z] | Size / Dimension [z] | Size / Dimension [y] | Size / Dimension [x] | Size / Dimension [y] | Size / Dimension [x] | Voltage - Output 2 | Voltage - Output 3 | Current - Output 1 | Mounting Type | Voltage - Output 4 | Current - Output 2 [custom] |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Integrated Power Designs | 2 A | CE cURus TUV UKCA | 60601-1 62368-1 | Chassis | ITE (Commercial) Medical | -20 °C | 70 °C | 5 V | 2 A | 200 W | Adjustable Output Remote Sense Universal Input | 8 A | 4 | 89 % | 1.65 " | 41.9 mm | 79.9 mm | 127 mm | 3.14 in | 5 in | 3.3 V | 12 V | 30 A | Chassis Mount | |||
Integrated Power Designs | 2 A | CE cURus TUV UKCA | 60601-1 62368-1 | Chassis | ITE (Commercial) Medical | -20 °C | 70 °C | 5 V | 2 A | 200 W | Adjustable Output Remote Sense Universal Input | 3 A | 4 | 89 % | 1.65 " | 41.9 mm | 79.9 mm | 127 mm | 3.14 in | 5 in | 24 V | 15 V | 30 A | Chassis Mount | -15 V | ||
Integrated Power Designs | CE cURus TUV UKCA | 60601-1 62368-1 | Chassis | ITE (Commercial) Medical | -20 °C | 70 °C | 5 V | 200 W | Adjustable Output Remote Sense Universal Input | 1.5 A | 3 | 89 % | 1.65 " | 41.9 mm | 79.9 mm | 127 mm | 3.14 in | 5 in | 24 V | -24 V | 30 A | Chassis Mount | |||||
Integrated Power Designs | CE cURus TUV UKCA | 60601-1 62368-1 | Chassis | ITE (Commercial) Medical | -20 °C | 70 °C | 12 V | 216 W | Adjustable Output Remote Sense Universal Input | 2 | 89 % | 1.65 " | 41.9 mm | 79.9 mm | 127 mm | 3.14 in | 5 in | -12 V | 12 A | Chassis Mount | 6 A | ||||||
Integrated Power Designs | CE cURus TUV UKCA | 60601-1 62368-1 | Chassis | ITE (Commercial) Medical | -20 °C | 70 °C | 5 V | 222 W | Adjustable Output Remote Sense Universal Input | 2 | 89 % | 1.65 " | 41.9 mm | 79.9 mm | 127 mm | 3.14 in | 5 in | 12 V | 30 A | Chassis Mount | 6 A | ||||||
Integrated Power Designs | CE cURus TUV UKCA | 60601-1 62368-1 | Enclosed | ITE (Commercial) Medical | -20 °C | 70 °C | 12 V | 200 W | Adjustable Output Remote Sense Universal Input | 2 | 89 % | 1.65 " | 41.9 mm | 79.9 mm | 127 mm | 3.14 in | 5 in | -12 V | 12 A | Chassis Mount | 6 A | ||||||
Integrated Power Designs | 2 A | CE cURus TUV UKCA | 60601-1 62368-1 | Enclosed | ITE (Commercial) Medical | -20 °C | 70 °C | 5 V | 2 A | 200 W | Adjustable Output Remote Sense Universal Input | 8 A | 4 | 89 % | 1.65 " | 41.9 mm | 79.9 mm | 127 mm | 3.14 in | 5 in | 3.3 V | 12 V | 30 A | Chassis Mount | |||
Integrated Power Designs | CE cURus TUV UKCA | 60601-1 62368-1 | Enclosed | ITE (Commercial) Medical | -20 °C | 70 °C | 5 V | 200 W | Adjustable Output Remote Sense Universal Input | 3 A | 2 | 89 % | 1.65 " | 41.9 mm | 79.9 mm | 127 mm | 3.14 in | 5 in | 25 V | 30 A | Chassis Mount | ||||||
Integrated Power Designs | 2 A | CE cURus TUV UKCA | 60601-1 62368-1 | Chassis | ITE (Commercial) Medical | -20 °C | 70 °C | 5 V | 200 W | Adjustable Output Remote Sense Universal Input | 5 A | 3 | 89 % | 1.18 in | 30 mm | 76.2 mm | 127 mm | 3 " | 5 in | 15 V | -15 V | 30 A | Chassis Mount | ||||
Integrated Power Designs | 2 A | CE cURus TUV UKCA | 60601-1 62368-1 | Enclosed | ITE (Commercial) Medical | -20 °C | 70 °C | 5 V | 2 A | 200 W | Adjustable Output Remote Sense Universal Input | 3 A | 4 | 89 % | 1.65 " | 41.9 mm | 79.9 mm | 127 mm | 3.14 in | 5 in | 24 V | 12 V | 30 A | Chassis Mount |
Pricing
Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly
Description
General part information
GRN-200 Series
Chassis AC DC Converters 4 Output 5V 3.3V 12V -12V 85 ~ 264 VAC Input
Documents