| Circuit Breakers | 1 | 1 | Circuit Breakers Circuit BreakerS | |
E-T-A106-M2Circuit Breakers Miniaturised single pole thermal circuit breaker with push-to-reset tease free, trip-free, snap action mechanism (R-type TO CBE to EN 60934), threadneck mounting. Approved to CBE standard EN 60934 (IEC 60934). For higher current ratings | Circuit Protection | 2 | 1 | Circuit Breakers Miniaturised single pole thermal circuit breaker with push-to-reset tease free, trip-free, snap action mechanism (R-type TO CBE to EN 60934), threadneck mounting. Approved to CBE standard EN 60934 (IEC 60934). For higher current ratings |
E-T-A1110-Fx12-P1M1Circuit Breakers Single pole switch/thermal circuit breaker (S-type TO CBE to EN 60934) with tease-free, trip-free, snap action mechanism. Designed for snap-in panel mounting utilising round hole or industry standard fuse-holder cut-out dimensions. Featu | Circuit Protection | 2 | 1 | Circuit Breakers Single pole switch/thermal circuit breaker (S-type TO CBE to EN 60934) with tease-free, trip-free, snap action mechanism. Designed for snap-in panel mounting utilising round hole or industry standard fuse-holder cut-out dimensions. Featu |
E-T-A1115Circuit Breakers Single pole thermal reset circuit breaker providing reliable trip-free mechanism. Its ultra-slim design makes it ideally suited for replacing closed vertical fuse holders. Snap-in frame for ease in installation. For requirements less tha | Circuit Protection | 1 | 8 | Circuit Breakers Single pole thermal reset circuit breaker providing reliable trip-free mechanism. Its ultra-slim design makes it ideally suited for replacing closed vertical fuse holders. Snap-in frame for ease in installation. For requirements less tha |
E-T-A1140Circuit Breakers Miniaturised double pole thermal circuit breaker with push-to-reset tease-free, trip-free, snap action mechanism (R-type TO CBE to EN 60934). Threadneck panel mounting. Suitable for line and neutral switching - the thermal actuator opera | Circuit Breakers | 2 | 1 | Circuit Breakers Miniaturised double pole thermal circuit breaker with push-to-reset tease-free, trip-free, snap action mechanism (R-type TO CBE to EN 60934). Threadneck panel mounting. Suitable for line and neutral switching - the thermal actuator opera |
| Circuit Breakers | 1 | 1 | Circuit Breakers 1077, 1P, plug, 250VAC/72VDC, T, w/switch function, 0.7A | |
E-T-A127Circuit Breakers Single pole thermal circuit breaker with push-to-reset, tease-free, trip-free, snap action mechanism (R-type TO CBE to EN 60934; M-type when fitted with optional manual release feature). Available in versions for plug-in or integral moun | Circuit Protection | 2 | 1 | Circuit Breakers Single pole thermal circuit breaker with push-to-reset, tease-free, trip-free, snap action mechanism (R-type TO CBE to EN 60934; M-type when fitted with optional manual release feature). Available in versions for plug-in or integral moun |
E-T-A129Circuit Breakers Single pole thermal circuit breaker with push-to-reset, tease-free, trip-free, snap action mechanism and separate manual release (M-type TO CBE to EN 60934). Designed for bolt-on mounting with terminal block type 83-P10. | Circuit Protection | 1 | 1 | Circuit Breakers Single pole thermal circuit breaker with push-to-reset, tease-free, trip-free, snap action mechanism and separate manual release (M-type TO CBE to EN 60934). Designed for bolt-on mounting with terminal block type 83-P10. |
E-T-A1410-F1Circuit Breakers Miniaturised single pole rocker switch/thermal circuit breaker combining ON/OFF switching and extremely fast overload performance in a single component (S-type TO CBE to EN 60934/IEC 934). Under overload conditions an internal neon (fila | Unclassified | 2 | 1 | Circuit Breakers Miniaturised single pole rocker switch/thermal circuit breaker combining ON/OFF switching and extremely fast overload performance in a single component (S-type TO CBE to EN 60934/IEC 934). Under overload conditions an internal neon (fila |
E-T-A1410-L2Circuit Breakers Single pole press-to-reset thermal circuit breaker with extremely fast overload switching performance (R-type TO CBE to EN 60934), PCB mounting. Miniaturised construction minimises PCB real estate required. Type 1410-L2 features changeov | Circuit Breakers | 2 | 1 | Circuit Breakers Single pole press-to-reset thermal circuit breaker with extremely fast overload switching performance (R-type TO CBE to EN 60934), PCB mounting. Miniaturised construction minimises PCB real estate required. Type 1410-L2 features changeov |
| Part | Voltage Rating - AC | Current Rating (Amps) | Breaker Type | Approval Agency | Voltage Rating - DC | Actuator Type | Illumination | Number of Poles | Mounting Type |
|---|---|---|---|---|---|---|---|---|---|
250 V | 20 A | Thermal | CSA C22.2 No 235 GB 17701 IEC 60934 UL1077 | 50 VDC | Rocker | None | 2 | ||
E-T-A | 250 V | 10 A | Thermal | CSA C22.2 No 235 GB 17701 IEC 60934 UL1077 | 50 VDC | Push to Reset | None | 1 | |
250 V | 5 A | Thermal | CSA C22.2 No 235 GB 17701 IEC 60934 UL1077 | 50 VDC | Rocker | None | 2 | ||
250 V | 18 A | Thermal | CSA C22.2 No 235 GB 17701 IEC 60934 UL1077 | 50 VDC | Rocker | None | 2 | ||
415 V | 20 A | Thermal | CSA C22.2 No 235 GB 17701 IEC 60934 UL1077 | 50 VDC | Rocker | None | 2 | ||
250 V | 10 A | Magnetic (Hydraulic Delay) | CSA C22.2 No 235 GB 17701 IEC 60934 UL1077 UL489A | 80 V | Lever | None | 1 | DIN Rail | |
480 V | 25 A | Thermal Magnetic | CSA C22.2 No 235 GB 17701 IEC 60934 UL1077 | 65 VDC | Lever | None | 1 | DIN Rail | |
480 V | 100 mA | Thermal Magnetic | CSA C22.2 No 235 GB 17701 IEC 60934 UL1077 | 65 VDC | Lever | None | 3 | ||
115 V | 2 A | Thermal | CSA C22.2 No 235 UL1077 | 28 V | Push-Pull Plunger | None | 1 | ||
480 V | 16 A | Thermal Magnetic | CSA C22.2 No 235 GB 17701 IEC 60934 UL1077 | 65 VDC | Lever | None | 1 | DIN Rail |