AC/DC CONVERTER 48V
| Part | Package / Case | Load Regulation | Number of Outputs | Current - Output (Max) [Max] | Applications | Line Regulation | Voltage - Output 1 | Operating Temperature [Max] | Operating Temperature [Min] | Mounting Type | Voltage - Input [Max] | Voltage - Input [Min] | Type | Approval Agency | Size / Dimension [z] | Size / Dimension [y] | Size / Dimension [z] | Size / Dimension [y] | Size / Dimension [x] | Size / Dimension [x] | Voltage - Isolation | Size / Dimension [y] | Size / Dimension [z] | Current - Output 1 | Features | Line Regulation |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Polytron | 7-DIP Module 5 Leads | 0.2 % | 1 | 100 mA | Medical | ±0.2% | 48 V | 85 °C | -40 °C | Through Hole | 125 VAC | 105 VAC | Enclosed | CE cURus | 1.25 " | 2.5 in | 31.8 mm | 63.5 mm | 3.5 in | 88.9 mm | ||||||
Polytron | 1 | Medical | 48 V | 71 °C | -25 °C | Chassis Mount | 125 VAC | 105 VAC | Enclosed | CE cURus | 1.25 " | 2.5 in | 4.1 " | 104.1 mm | 4000 V | 63.5 mm | 31.8 mm | 100 mA | ||||||||
Polytron | 7-DIP Module 5 Leads | 0.2 % | 1 | 100 mA | ITE (Commercial) | 48 V | 71 °C | -25 °C | Through Hole | 125 VAC | 105 VAC | Enclosed | CE cURus UL | 1.25 " | 2.5 in | 31.8 mm | 63.5 mm | 3.5 in | 88.9 mm | SCP | 0.2 % | |||||
Polytron | 1 | Medical | 48 V | 71 °C | -25 °C | Chassis Mount | 125 VAC | 105 VAC | Enclosed | CE cURus | 1.25 " | 2.5 in | 4.1 " | 104.1 mm | 4000 V | 63.5 mm | 31.8 mm | 100 mA | ||||||||
Polytron | 7-DIP Module 5 Leads | 0.2 % | 1 | 100 mA | Medical | ±0.2% | 48 V | 71 °C | -25 °C | Through Hole | 240 VAC | 105 VAC | Enclosed | CE cURus | 1.25 " | 2.5 in | 31.8 mm | 63.5 mm | 3.5 in | 88.9 mm | ||||||
Polytron | 7-DIP Module 5 Leads | 0.2 % | 1 | 100 mA | Medical | ±0.2% | 48 V | 71 °C | -25 °C | Through Hole | 220 VAC | 105 VAC | Enclosed | CE cURus | 1.25 " | 2.5 in | 31.8 mm | 63.5 mm | 3.5 in | 88.9 mm | ||||||
Polytron | 7-DIP Module 5 Leads | 0.2 % | 1 | 100 mA | Medical | ±0.2% | 48 V | 71 °C | -25 °C | Through Hole | 230 VAC/DC | 105 VAC | Enclosed | CE cURus | 1.25 " | 2.5 in | 31.8 mm | 63.5 mm | 3.5 in | 88.9 mm | ||||||
Polytron | 7-DIP Module 5 Leads | 0.2 % | 1 | 100 mA | Medical | ±0.2% | 48 V | 71 °C | -25 °C | Through Hole | 220 VAC | 100 VAC | Enclosed | CE cURus | 1.25 " | 2.5 in | 31.8 mm | 63.5 mm | 3.5 in | 88.9 mm | ||||||
Polytron | 7-DIP Module 5 Leads | 0.2 % | 1 | 100 mA | Medical | ±0.2% | 48 V | 71 °C | -25 °C | Through Hole | 220 VAC | 115 VAC | Enclosed | CE cURus | 1.25 " | 2.5 in | 31.8 mm | 63.5 mm | 3.5 in | 88.9 mm | ||||||
Polytron | 7-DIP Module 5 Leads | 0.2 % | 1 | 100 mA | Medical | ±0.2% | 48 V | 71 °C | -25 °C | Through Hole | 125 VAC | 100 VAC | Enclosed | CE cURus | 1.25 " | 2.5 in | 31.8 mm | 63.5 mm | 3.5 in | 88.9 mm |