REM2-3.312 Series
Isolated DC/DC Converters - Through Hole 2W 05Vin 05Vout 400mA
Manufacturer: RECOM Power
Catalog
Isolated DC/DC Converters - Through Hole 2W 05Vin 05Vout 400mA
Isolated DC/DC Converters - Through Hole 2W 05Vin 05Vout 400mA
Isolated DC/DC Converters - Through Hole 2W 05Vin 05Vout 400mA
Isolated DC/DC Converters - Through Hole 2W 05Vin 05Vout 400mA
| Part | Voltage - Isolation | Power (Watts) | Voltage - Input (Max) [Max] | Voltage - Input (Min) [Min] | Type | Voltage - Output 1 | Approval Agency | Mounting Type | Number of Outputs | Applications | Features | Size / Dimension [x] | Size / Dimension [y] | Size / Dimension [z] | Size / Dimension [z] | Size / Dimension [x] | Size / Dimension [y] | Voltage - Output 2 | Operating Temperature [Min] | Operating Temperature [Max] | Package / Case | Package / Case | Current - Output (Max) | Current - Output (Max) | Efficiency | Current - Output (Max) [Max] |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RECOM Power | 5.2 kV | 2 W | 5.5 V | 4.5 V | Isolated Module | 5 V | CB cURus | Through Hole | 2 | ITE (Commercial) Medical | OCP | 0.91 " | 0.31 " | 0.48 in | 12.2 mm | 23 mm | 8 mm | -5 V | -40 °C | 95 °C | 5 Leads | 8-SIP Module | ||||
RECOM Power | 5.2 kV | 2 W | 3.63 V | 2.97 V | Isolated Module | 12 V | CB cURus | Through Hole | 2 | ITE (Commercial) Medical | OCP | 0.91 " | 0.31 " | 0.48 in | 12.2 mm | 23 mm | 8 mm | -12 V | -40 °C | 95 °C | 5 Leads | 8-SIP Module | 84 mA | 84 mA | 85 % | |
RECOM Power | 5.2 kV | 2 W | 13.2 V | 10.8 V | Isolated Module | 12 V | CB cURus | Through Hole | 2 | ITE (Commercial) Medical | OCP | 0.91 " | 0.31 " | 0.48 in | 12.2 mm | 23 mm | 8 mm | -12 V | -40 °C | 95 °C | 5 Leads | 8-SIP Module | 84 mA | 84 mA | 85 % | |
RECOM Power | 5.2 kV | 2 W | 26.4 V | 21.6 V | Isolated Module | 3.3 V | CB cURus | Through Hole | 1 | ITE (Commercial) Medical | OCP | 0.91 " | 0.31 " | 0.48 in | 12.2 mm | 23 mm | 8 mm | -40 °C | 95 °C | 8-SIP Module 4 Leads | 77 % | 606 mA | ||||
RECOM Power | 5.2 kV | 2 W | 5.5 V | 4.5 V | Isolated Module | 12 V | CB cURus | Through Hole | 1 | ITE (Commercial) Medical | OCP | 0.91 " | 0.31 " | 0.48 in | 12.2 mm | 23 mm | 8 mm | -40 °C | 95 °C | 8-SIP Module 4 Leads | 167 mA | |||||
RECOM Power | 5.2 kV | 2 W | 16.5 V | 13.5 V | Isolated Module | 9 V | CB cURus | Through Hole | 1 | ITE (Commercial) Medical | OCP | 0.91 " | 0.31 " | 0.48 in | 12.2 mm | 23 mm | 8 mm | -40 °C | 95 °C | 8-SIP Module 4 Leads | 84 % | 222 mA | ||||
RECOM Power | 5.2 kV | 2 W | 3.63 V | 2.97 V | Isolated Module | 9 V | CB cURus | Through Hole | 1 | ITE (Commercial) Medical | OCP | 0.91 " | 0.31 " | 0.48 in | 12.2 mm | 23 mm | 8 mm | -40 °C | 95 °C | 8-SIP Module 4 Leads | 84 % | 222 mA | ||||
RECOM Power | 5.2 kV | 2 W | 16.5 V | 13.5 V | Isolated Module | 12 V | CB cURus | Through Hole | 2 | ITE (Commercial) Medical | OCP | 0.91 " | 0.31 " | 0.48 in | 12.2 mm | 23 mm | 8 mm | -12 V | -40 °C | 95 °C | 5 Leads | 8-SIP Module | 84 mA | 84 mA | 85 % | |
RECOM Power | 5.2 kV | 2 W | 13.2 V | 10.8 V | Isolated Module | 9 V | CB cURus | Through Hole | 1 | ITE (Commercial) Medical | OCP | 0.91 " | 0.31 " | 0.48 in | 12.2 mm | 23 mm | 8 mm | -40 °C | 95 °C | 8-SIP Module 4 Leads | 84 % | 222 mA | ||||
RECOM Power | 5.2 kV | 2 W | 13.2 V | 10.8 V | Isolated Module | 5 V | CB cURus | Through Hole | 1 | ITE (Commercial) Medical | OCP | 0.91 " | 0.31 " | 0.48 in | 12.2 mm | 23 mm | 8 mm | -40 °C | 95 °C | 8-SIP Module 4 Leads | 79 % | 400 mA |