AC/DC CONVERTER 5V 12W
| Part | Approval Agency | Voltage - Input [Min] | Voltage - Input [Max] | Line Regulation | Voltage - Output 1 | Type | Mounting Type | Power (Watts) | Load Regulation | Current - Output (Max) [Max] | Applications | Package / Case | Efficiency | Standard Number | Features | Size / Dimension [x] | Size / Dimension [z] | Size / Dimension [x] | Size / Dimension [y] | Size / Dimension [y] | Size / Dimension [z] | Operating Temperature [Min] | Operating Temperature [Max] | Number of Outputs |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Astrodyne TDI | cURus UL | 90 VAC | 264 VAC | 0.5 % | 5 V | Open Frame | Through Hole | 12 W | 1 % | 2.4 A | ITE (Commercial) Medical | 4-DIP Module | 72 % | 60601-1 60950-1 | Universal Input | 2.06 in | 0.91 in | 52.3 mm | 27.2 mm | 1.07 in | 23 mm | -20 °C | 70 °C | 1 |
Astrodyne TDI | cURus UL | 90 VAC | 264 VAC | 0.5 % | 5 V | Open Frame | Through Hole | 12 W | 1 % | 2.4 A | ITE (Commercial) Medical | 6-SIP Module | 72 % | 60601-1 60950-1 | Universal Input | 2 in | 1.12 in | 50.8 mm | 17.5 mm | 0.69 " | 28.5 mm | -20 °C | 70 °C | 1 |
Astrodyne TDI | cURus UL | 90 VAC | 264 VAC | 0.5 % | 12 V | Open Frame | Through Hole | 12 W | 1 % | 1 A | ITE (Commercial) Medical | 4-DIP Module | 75 % | 60601-1 60950-1 | Universal Input | 2.06 in | 0.91 in | 52.3 mm | 27.2 mm | 1.07 in | 23 mm | -20 °C | 70 °C | 1 |
Astrodyne TDI | cURus UL | 90 VAC | 264 VAC | 0.5 % | 15 V | Enclosed | Through Hole | 12 W | 1 % | 800 mA | ITE (Commercial) Medical | 6-SIP Module | 75 % | 60601-1 60950-1 | Universal Input | 2.11 " | 1.24 " | 53.6 mm | 23.3 mm | 0.92 " | 31.5 mm | -20 °C | 70 °C | 1 |
Astrodyne TDI | CB CE cURus UL | 90 VAC | 264 VAC | 0.5 % | 15 V | Enclosed | Through Hole | 12 W | 1 % | 800 mA | ITE (Commercial) | 4-DIP Module | 80 % | Universal Input | 2.06 in | 0.91 in | 52.4 mm | 27.2 mm | 1.07 in | 23 mm | -20 °C | 70 °C | 1 | |
Astrodyne TDI | CB CE cURus UL | 90 VAC | 264 VAC | 0.5 % | 24 V | Enclosed | Through Hole | 12 W | 1 % | 500 mA | ITE (Commercial) | 4-DIP Module | Universal Input | 2.06 in | 0.91 in | 52.4 mm | 27.2 mm | 1.07 in | 23 mm | -20 °C | 70 °C | 1 | ||
Astrodyne TDI | cURus UL | 90 VAC | 264 VAC | 0.5 % | 48 V | Open Frame | Through Hole | 12 W | 1 % | 250 mA | ITE (Commercial) Medical | 4-DIP Module | 77 % | 60601-1 60950-1 | Universal Input | 2.06 in | 0.91 in | 52.3 mm | 27.2 mm | 1.07 in | 23 mm | -20 °C | 70 °C | 1 |
Astrodyne TDI | CB CE cURus UL | 90 VAC | 264 VAC | 0.5 % | 3.3 V | Enclosed | Through Hole | 10 W | 1 % | 3.01 A | ITE (Commercial) | 4-DIP Module | 72 % | Universal Input | 2.06 in | 0.91 in | 52.4 mm | 27.2 mm | 1.07 in | 23 mm | -20 °C | 70 °C | 1 | |
Astrodyne TDI | cURus UL | 90 VAC | 264 VAC | 0.5 % | 5 V | Enclosed | Through Hole | 12 W | 1 % | 2.4 A | ITE (Commercial) Medical | 6-SIP Module | 72 % | 60601-1 60950-1 | Universal Input | 2.11 " | 1.24 " | 53.6 mm | 23.3 mm | 0.92 " | 31.5 mm | -20 °C | 70 °C | 1 |
Astrodyne TDI | CB CE cURus UL | 90 VAC | 264 VAC | 0.5 % | 5 V | Enclosed | Through Hole | 12 W | 1 % | 2.4 A | ITE (Commercial) | 4-DIP Module | 75 % | Universal Input | 2.06 in | 0.91 in | 52.4 mm | 27.2 mm | 1.07 in | 23 mm | -20 °C | 70 °C | 1 |