AC/DC OPEN FRAME POWER SUPPLY (PSU), MEDICAL, 1 OUTPUT, 500W, 250 W, 90V AC TO 264V AC, FIXED
| Part | Operating Temperature [Max] | Operating Temperature [Min] | Number of Outputs | Mounting Type | Voltage - Input [Min] | Voltage - Input [Max] | Applications | Power (Watts) | Type | Current - Output 1 | Efficiency | Features | Size / Dimension [x] | Size / Dimension [z] | Size / Dimension [y] | Size / Dimension [z] | Size / Dimension [x] | Size / Dimension [y] | Voltage - Isolation | Voltage - Output 1 | Size / Dimension [z] | Size / Dimension [z] | Size / Dimension [x] | Size / Dimension [y] |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TDK-LAMBDA | 70 °C | 0 °C | 1 | Chassis Mount | 90 VAC | 264 VAC | ITE (Commercial) Medical | 250 W 500 W | Open Frame | 20.8 A | 92 % | Universal Input | 180 mm | 39.5 mm | 107 mm | 1.56 in | 7.09 in | 4.21 in | 4000 V | 24 V | ||||
TDK-LAMBDA | 70 °C | 0 °C | 1 | Chassis Mount | 90 VAC | 264 VAC | ITE (Commercial) Medical | 250 W 500 W | Open Frame | 13.8 A | 92 % | Universal Input | 102 mm | 180 mm | 4000 V | 36 V | 1.46 " | 37 mm | 7.1 " | 4 " | ||||
TDK-LAMBDA | 70 °C | 0 °C | 1 | Chassis Mount | 90 VAC | 264 VAC | ITE (Commercial) Medical | 250 W 500 W | Open Frame | 13.8 A | 92 % | Universal Input | 102 mm | 180 mm | 4000 V | 36 V | 1.46 " | 37 mm | 7.1 " | 4 " | ||||
TDK-LAMBDA | 70 °C | 0 °C | 1 | Chassis Mount | 90 VAC | 264 VAC | ITE (Commercial) Medical | 250 W 500 W | Open Frame | 10.4 A | 92 % | Universal Input | 180 mm | 39.5 mm | 107 mm | 1.56 in | 7.09 in | 4.21 in | 4000 V | 48 V | ||||
TDK-LAMBDA | 70 °C | 0 °C | 1 | Chassis Mount | 90 VAC | 264 VAC | ITE (Commercial) Medical | 250 W 500 W | Open Frame | 10.4 A | 92 % | Universal Input | 102 mm | 180 mm | 4000 V | 48 V | 1.46 " | 37 mm | 7.1 " | 4 " | ||||
TDK-LAMBDA | 70 °C | 0 °C | 1 | Chassis Mount | 90 VAC | 264 VAC | ITE (Commercial) Medical | 500 W | Enclosed | 13.8 A | 92 % | Universal Input | 4000 V | 36 V | ||||||||||
TDK-LAMBDA | 70 °C | 0 °C | 1 | Chassis Mount | 90 VAC | 264 VAC | ITE (Commercial) Medical | 250 W 500 W | Open Frame | 13.8 A | 92 % | Universal Input | 180 mm | 39.5 mm | 107 mm | 1.56 in | 7.09 in | 4.21 in | 4000 V | 36 V | ||||
TDK-LAMBDA | 70 °C | 0 °C | 1 | Chassis Mount | 90 VAC | 264 VAC | ITE (Commercial) Medical | 250 W 500 W | Open Frame | 13.8 A | 92 % | Universal Input | 180 mm | 39.5 mm | 107 mm | 1.56 in | 7.09 in | 4.21 in | 4000 V | 36 V | ||||
TDK-LAMBDA | 70 °C | 0 °C | 1 | Chassis Mount | 90 VAC | 264 VAC | ITE (Commercial) Medical | 250 W 500 W | Open Frame | 10.4 A | 92 % | Universal Input | 102 mm | 180 mm | 4000 V | 48 V | 1.46 " | 37 mm | 7.1 " | 4 " |