Zenode.ai Logo
Beta
K

4A24-P30 Series

Non-Isolated DC/DC Converters A-Series DC to HVDC Converter, Single output (Unipolar), +24V Input, , -6000V DC HVout, 30W, Thru-hole mount, Regulated, I10 Interface 0 to +10 VDC Monitors/Controls, Mu Metal shield, Heatsink

Catalog

Non-Isolated DC/DC Converters A-Series DC to HVDC Converter, Single output (Unipolar), +24V Input, , -6000V DC HVout, 30W, Thru-hole mount, Regulated, I10 Interface 0 to +10 VDC Monitors/Controls, Mu Metal shield, Heatsink

...
PartApproval AgencyVoltage - Input (Min) [Min]Control FeaturesStandard NumberMounting TypeOperating Temperature [Min]Operating Temperature [Max]Number of OutputsSize / Dimension [z]Size / Dimension [y]Size / Dimension [z]Size / Dimension [x]Size / Dimension [x]Size / Dimension [y]Power (Watts)ApplicationsVoltage - Input (Max) [Max]TypePackage / CaseCurrent - Output (Max) [Max]Size / Dimension [y]Size / Dimension [z]Voltage - Output 1 [Max]Voltage - Output 1 [Min]FeaturesVoltage - Output 1
ULTRAVOLT / Advanced Energy
CE
cURus
23 V
Active Low
Enable
60950-1
62368-1
Through Hole
10 °C
45 °C
1
21.9 mm
38.9 mm
0.86 in
94.8 mm
3.73 in
1.53 in
15 W
ITE (Commercial)
30 V
High Voltage - Non-Isolated Module
11-DIP Module
480 mA
ULTRAVOLT / Advanced Energy
CE
cURus
23 V
60950-1
62368-1
Chassis Mount
-40 °C
65 °C
1
1 "
120.7 mm
4.75 "
2 in
20 W
ITE (Commercial)
30 V
Enclosed
320 mA
50.8 mm
25.4 mm
ULTRAVOLT / Advanced Energy
CE
cURus
23 V
Active High
Enable
Through Hole
10 °C
45 °C
1
1 "
120.7 mm
4.75 "
2 in
4 W
ITE (Commercial)
30 V
High Voltage - Non-Isolated Module
Module
2 mA
50.8 mm
25.4 mm
2000 V
0 V
Adjustable Output
Remote On/Off
ULTRAVOLT / Advanced Energy
ULTRAVOLT / Advanced Energy
CE
cURus
23 V
Active Low
Enable
Through Hole
-40 °C
65 °C
1
1 "
120.7 mm
4.75 "
2 in
20 W
ITE (Commercial)
30 V
High Voltage - Non-Isolated Module
Module
20 mA
50.8 mm
25.4 mm
1000 V
0 V
Adjustable Output
Remote On/Off
ULTRAVOLT / Advanced Energy
CE
cURus
11 V
Active High
Enable
60950-1
62368-1
Through Hole
-40 °C
65 °C
1
30.5 mm
38.9 mm
1.2 "
94.8 mm
3.73 in
1.53 in
15 W
ITE (Commercial)
16 V
High Voltage - Non-Isolated Module
11-DIP Module
32 mA
Heat Sink
125 V
ULTRAVOLT / Advanced Energy
CE
cURus
23 V
60950-1
62368-1
Chassis Mount
10 °C
45 °C
1
1 "
120.7 mm
4.75 "
2 in
20 W
ITE (Commercial)
30 V
Enclosed
50.8 mm
25.4 mm
125 V
ULTRAVOLT / Advanced Energy
CE
cURus
23 V
60950-1
62368-1
Chassis Mount
10 °C
45 °C
1
1 "
120.7 mm
4.75 "
2 in
20 W
ITE (Commercial)
30 V
Enclosed
40 mA
50.8 mm
25.4 mm
500 V
ULTRAVOLT / Advanced Energy
CE
cURus
23 V
Active Low
Enable
60950-1
62368-1
Through Hole
-40 °C
65 °C
1
0.83 in
94 mm
3.7 in
1.5 in
15 W
ITE (Commercial)
30 V
High Voltage - Non-Isolated Module
11-DIP Module
240 mA
38.1 mm
21.2 mm
125 V
ULTRAVOLT / Advanced Energy
CE
cURus
11 V
60950-1
62368-1
Chassis Mount
10 °C
45 °C
1
1 "
120.7 mm
4.75 "
2 in
4 W
ITE (Commercial)
16 V
Enclosed
64 mA
50.8 mm
25.4 mm