AC/DC CONVERTER 5V 160W
| Part | Number of Outputs | Type | Power (Watts) | Voltage - Output 1 | Operating Temperature [Max] | Operating Temperature [Min] | Voltage - Isolation | Applications | Mounting Type | Features | Approval Agency | Voltage - Input [Min] | Voltage - Input [Max] | Current - Output 1 | Size / Dimension [y] | Size / Dimension [z] | Size / Dimension [z] | Size / Dimension [y] | Size / Dimension [x] | Size / Dimension [x] | Efficiency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MEAN WELL USA Inc. | 1 | Enclosed | 160 W | 5 V | 70 °C | -30 °C | 3750 V | ITE (Commercial) | Chassis Mount | Adjustable Output DC Input Capable Load Sharing PFC | CB CCC CE cURus EAC TUV | 100 VAC 141 VDC | 264 VAC 370 VDC | 32 A | 2.17 in | 0.79 in | 20 mm | 55 mm | 7.64 in | 194 mm | |
MEAN WELL USA Inc. | 1 | Enclosed | 162 W | 12 V | 70 °C | -30 °C | 3750 V | ITE (Commercial) | Chassis Mount | Adjustable Output PFC | CB CCC CE cURus EAC TUV | 100 VAC 141 VDC | 264 VAC 370 VDC | 13.5 A | 2.17 in | 0.79 in | 20 mm | 55 mm | 7.64 in | 194 mm | 92.5 % |
MEAN WELL USA Inc. | 1 | Enclosed | 106 W | 3.3 V | 70 °C | -30 °C | 3750 V | ITE (Commercial) | Chassis Mount | Adjustable Output PFC | CB CCC CE cURus EAC TUV | 100 VAC 141 VDC | 264 VAC 370 VDC | 32 A | 2.17 in | 0.79 in | 20 mm | 55 mm | 7.64 in | 194 mm | 87.5 % |
MEAN WELL USA Inc. | 1 | Enclosed | 134 W | 4.2 V | 70 °C | -30 °C | 3750 V | ITE (Commercial) | Chassis Mount | Adjustable Output DC Input Capable Load Sharing PFC | CB CCC CE cURus EAC TUV | 100 VAC 141 VDC | 264 VAC 370 VDC | 32 A | 2.17 in | 0.79 in | 20 mm | 55 mm | 7.64 in | 194 mm | 88.5 % |
MEAN WELL USA Inc. | 1 | Enclosed | 163 W | 48 V | 70 °C | -30 °C | 3750 V | ITE (Commercial) | Chassis Mount | Adjustable Output PFC | CB CCC CE cURus EAC TUV | 100 VAC 141 VDC | 264 VAC 370 VDC | 3.4 A | 2.17 in | 0.79 in | 20 mm | 55 mm | 7.64 in | 194 mm | 93.5 % |
MEAN WELL USA Inc. | 1 | Enclosed | 162 W | 36 V | 70 °C | -30 °C | 3750 V | ITE (Commercial) | Chassis Mount | Adjustable Output PFC | CB CCC CE cURus EAC TUV | 100 VAC 141 VDC | 264 VAC 370 VDC | 4.5 A | 2.17 in | 0.79 in | 20 mm | 55 mm | 7.64 in | 194 mm | 93.5 % |
MEAN WELL USA Inc. | 1 | Enclosed | 162 W | 24 V | 70 °C | -30 °C | 3750 V | ITE (Commercial) | Chassis Mount | Adjustable Output PFC | CB CCC CE cURus EAC TUV | 100 VAC 141 VDC | 264 VAC 370 VDC | 6.75 A | 2.17 in | 0.79 in | 20 mm | 55 mm | 7.64 in | 194 mm | 93.5 % |
MEAN WELL USA Inc. | 1 | Enclosed | 160 W | 5 V | 70 °C | -30 °C | 3750 V | ITE (Commercial) | Chassis Mount | Adjustable Output PFC | CB CCC CE cURus EAC TUV | 100 VAC 141 VDC | 264 VAC 370 VDC | 32 A | 2.17 in | 0.79 in | 20 mm | 55 mm | 7.64 in | 194 mm |